Concurrence of 1- and 3-Min Sit-to-Stand Tests with the 6-Min Walk Test in Idiopathic Pulmonary Fibrosis.
Background
In idiopathic pulmonary fibrosis (IPF), some physiological parameters measured during a 6-min walk test (6-MWT) impart reliable prognostic information. Sit-to-stand tests (STSTs) are field exercise tests that are easier to implement than the 6-MWT in daily practice.
Objectives
The aims of the study were to test the reproducibility and compare 2 STSTs (the 1-min STST [1-STST] and the semi-paced 3-min chair rise test [3-CRT]) in IPF, and to determine if selected physiological parameters (speed of displacement and changes in pulse oxygen saturation [SpO2]) are interchangeable between the STSTs and the 6-MWT.
Methods
Thirty-three patients with stable IPF were studied in 3 French expert centers. To test reproducibility, intra-class correlations (ICCs) of parameters measured during tests performed 7-14 days apart were calculated. To test interchangeability, the agreement and correlation of physiological responses measured during STSTs and during 6-MWT were studied.
Results
Vertical displacements and changes in SpO2 during both STSTs were reproducible, with ICCs ranging from 0.78 [0.63-0.87] to 0.95 [0.92-0.97]. Vertical displacements during 1-STST and 3-CRT were correlated with 6-MWT distance (correlation coefficients (r) of 0.72 and 0.77, respectively; p < 0.001). Similarly, correlations were found between changes in SpO2 measured during the 2 STSTs and the 6-MWT, with coefficients ranging from 0.73 to 0.91 (p < 0.001). Distance walked and SpO2 during 6-MWT were well estimated from vertical displacement and SpO2 during the 2 STSTs, respectively.
Conclusion
The correlations found between the 2 STSTs and the 6-MWT suggest that STSTs may be of interest to assess displacement and exercise-induced changes in SpO2 in IPF patients.
© 2021 S. Karger AG, Basel.
Overview publication
Title | Concurrence of 1- and 3-Min Sit-to-Stand Tests with the 6-Min Walk Test in Idiopathic Pulmonary Fibrosis. |
Date | 2021-01-01 |
Issue name | Respiration; international review of thoracic diseases |
Issue number | v100.7:571-579 |
DOI | 10.1159/000515335 |
PubMed | 33849043 |
Authors | |
Keywords | 6-min walk test, Idiopathic pulmonary fibrosis, Sit-to-stand tests |
Read | Read publication |