A newborn Screening Programme for Inborn errors of metabolism in Galicia: 22 years of evaluation and follow-up.

Background

There is a notable lack of harmonisation in newborn screening (NBS) programmes worldwide. The Galician programme for early detection of inborn errors of metabolism (IEM) was one of the first NBS programmes in Europe to incorporate mass spectrometry (July 2000). This programme currently screens for 26 IEMs in dried blood and urine samples collected 24-72 h after birth.

Results

In its 22-year history, this programme has analysed samples from 440,723 neonates and identified 326 cases of IEM with a prevalence of 1:1351. The most prevalent IEMs were hyperphenylalaninaemia (n = 118), followed by medium chain acyl-CoA dehydrogenase deficiency (MCADD, n = 26), galactosaemia (n = 20), and cystinurias (n = 43). Sixty-one false positives and 18 conditions related to maternal pathologies were detected. Urine samples have been identified as a useful secondary sample to reduce the rate of false positives and identify new defects. There were 5 false negatives. The overall positive value was 84.23%. The fatality rate over a median of 12.1 years of follow-up was 2.76%. The intelligence quotient of patients was normal in 95.7% of cases, and school performance was largely optimal, with pedagogic special needs assistance required in < 10% of cases. Clinical onset of disease preceded diagnosis in 4% of cases. The age at which first NBS report is performed was reduced by 4 days since 2021.

Conclusions

This study highlights the benefits of collecting urine samples, reduce NBS reporting time and expanding the number of IEMs included in NBS programmes.

© 2024. The Author(s).

Overview publication

TitleA newborn Screening Programme for Inborn errors of metabolism in Galicia: 22 years of evaluation and follow-up.
Date2024-05-17
Issue nameOrphanet journal of rare diseases
Issue numberv19.1:202
DOI10.1186/s13023-024-03204-y
PubMed38760795
AuthorsCouce ML, Bóveda MD, Castiñeiras DE, Vázquez-Mosquera ME, Barbosa-Gouveia S, De Castro MJ, Iglesias-Rodríguez AJ, Colón C, Cocho JA & Sánchez P
KeywordsAge at first NBS, Dried urine samples, Intelligence quotient, Mass spectrometry, Second biomarker